BS 6399 Part 1: A Guide for Dead Loads and Imposed Load (PDF)

BS 6399 Part 1 is a British Standard titled “Loading for buildings—Part 1: ‘Dead and imposed load code of practice’. It provides comprehensive procedures for calculating dead loads (permanent static weights) and imposed loads (temporary or variable loads) for building structures. This is an essential standard that architects, engineers, and construction professionals who work on building projects can refer to.

Adhering to BS 6399 Part 1 ensures that buildings can safely support permanent and variable loads during their lifespan. This compliance is vital for structural integrity, occupant safety, and meeting legal building regulations.

The standard classifies imposed loads based on building usage and occupancy, providing specific load values for each category.

Domestic and Residential Activities

The standard specifies minimum uniformly distributed and concentrated loads for areas like bedrooms, kitchens, and communal spaces in residential buildings.

Area TypeUniformly Distributed Load (kN/m²)Concentrated Load (kN)
Bedrooms and Dormitories1.51.8
Communal Kitchens3.04.5
Balconies (Single Dwelling)1.51.4

Offices and Work Areas

The standard provides load values for office spaces and work areas to account for typical office equipment and occupancy.

Area TypeUniformly Distributed Load (kN/m²)Concentrated Load (kN)
General Offices2.52.7
Banking Halls3.02.7
Kitchens, Laboratories3.04.5

Source: BS 6399-1:1996

Load Reductions

BS 6399 Part 1 allows for reductions in total imposed floor loads under specific conditions, such as:

  • Number of Storeys: Reductions are permitted based on the number of floors contributing to the load.
  • Floor Area: Larger floor areas may qualify for load reductions.

These reductions acknowledge that the probability of maximum loads occurring simultaneously across all floors or areas is low.

While primarily focusing on static loads, BS 6399 Part 1 also addresses dynamic loading, especially in scenarios involving crowd movements, machinery vibrations, or other dynamic forces. It provides guidance on accounting for these factors to ensure structural safety.

Despite being a British Standard, the principles outlined in BS 6399 Part 1 are applicable internationally, including in the United States. Understanding these guidelines can enhance the design and safety of structures worldwide.

For more detailed information, refer to the full text of BS 6399-1:1996.

Source: BS 6399-1:1996

Specific Use Cases of BS 6399 Part 1

Educational Buildings

In schools, colleges, and universities, BS 6399 Part 1 specifies load requirements based on the activities carried out in different areas. For example:

Area TypeUniformly Distributed Load (kN/m²)Concentrated Load (kN)
Classrooms3.02.7
Assembly Halls5.03.6
Libraries (General)4.04.5

This ensures structural stability in spaces where large groups gather, or heavy equipment and furniture are used.

Industrial and Storage Areas

The standard recognizes the higher loads associated with industrial activities and storage facilities. Key considerations include:

Area TypeUniformly Distributed Load (kN/m²)Concentrated Load (kN)
Light Industrial Areas5.03.6
Storage Areas (general)7.54.5
Heavy Machinery FloorsDesign-specificDesign-specific

Public Spaces

Public areas like shopping centers, theaters, and stadiums require load calculations for large crowds and specialized equipment:

Area TypeUniformly Distributed Load (kN/m²)Concentrated Load (kN)
Shopping Malls4.04.5
Theaters3.02.7
Sports Halls5.04.5

Compliance with BS 6399 Part 1

How to Ensure Compliance

To comply with BS 6399 Part 1, professionals should:

  • Review Building Usage: Understand the intended use and occupancy of the building.
  • Calculate Loads Accurately: Use the specified load values for each area type.
  • Consider Load Combinations: Account for both dead and imposed loads, as well as any dynamic forces.
  • Apply Reductions When Permitted: Take advantage of load reduction provisions where applicable.

Limitations of BS 6399 Part 1

While BS 6399 Part 1 provides robust guidance, it has certain limitations:

  • Regional Adaptability: It may require adjustments to align with specific local codes or environmental factors.
  • Dynamic Loads: Limited focus on dynamic loading scenarios like earthquakes or wind-induced vibrations.
  • Updates: Some professionals prefer newer standards, such as Eurocodes, for modern applications.

Bridging the Gap with Eurocodes

BS 6399 Part 1 is often compared with Eurocode 1, which provides a more comprehensive approach to loading. Understanding both standards allows professionals to select the best approach for their projects.

Comparison AspectBS 6399 Part 1Eurocode 1
Regional ApplicationPrimarily UKEurope-wide
Dynamic Load ConsiderationLimitedExtensive
Load CategoriesClear but traditionalModern and adaptable

Practical Examples of BS 6399 Part 1 in Action

Case Study: Residential Building

A residential developer used BS 6399 Part 1 to calculate imposed loads for a 10-story apartment building. They optimized structural material usage by applying load reductions for upper floors, reducing overall costs while maintaining safety.

Case Study: Office Tower

An engineering firm designing an office tower adhered to BS 6399 Part 1 for general office spaces but supplemented it with Eurocode 1 for wind loading analysis. This hybrid approach ensured compliance with both local and international standards.

Is BS 6399 Part 1 still relevant?

Although newer standards like Eurocodes exist, BS 6399 Part 1 remains a cornerstone for understanding and calculating building loads.

How does it differ from Eurocodes?

BS 6399 Part 1 is UK-specific, while Eurocodes provide a Europe-wide framework. The choice depends on the project location and requirements.

Can I use BS 6399 Part 1 for seismic design?

BS 6399 Part 1 primarily focuses on dead and imposed loads. For seismic considerations, professionals should refer to standards like Eurocode 8.

How does BS 6399 Part 1 address wind loads?

BS 6399 Part 1 primarily focuses on dead and imposed loads. Wind loads are covered separately under BS 6399 Part 2, which deals with wind actions on buildings.

How are load reductions applied in BS 6399 Part 1?

Load reductions are allowed for multi-story buildings based on:
The number of floors contributing to the load.
The total area over which the load is distributed.

How does BS 6399 relate to safety in construction?

BS 6399 ensures that buildings are designed to handle expected loads safely, preventing structural failures and ensuring the well-being of occupants.